TítuloPulsating heat pipes used for thermal control of electronics on surveillance systems
Ano2013
Data de Acesso19 maio 2024
Tipo SecundárioPRE CI
Número de Arquivos1
Tamanho1525 KiB
2. Contextualização
Autor1 Riehl, Roger Ribeiro
2 Cachuté, Liomar de Oliveira
Grupo1 DMC-ETE-INPE-MCTI-GOV-BR
2 CMC-ETES-SPG-INPE-MCTI-GOV-BR
Afiliação1 Instituto Nacional de Pesquisas Espaciais (INPE)
2 Instituto Nacional de Pesquisas Espaciais (INPE)
Endereço de e-Mail do Autor1 rriehl@dem.inpe.br
Endereço de e-Mailmarcelo.pazos@inpe.br
Nome do EventoInternational Conference on Environmental Systems, 43 (ICES).
Localização do EventoVail
Data14 -18 July 2013
Cidade da EditoraVail, CO
OrganizaçãoParagon
Histórico (UTC)2014-01-09 13:37:32 :: administrator -> marcelo.pazos@sid.inpe.br :: 2013
2014-01-10 11:06:09 :: marcelo.pazos@sid.inpe.br -> administrator :: 2013
2018-06-04 03:14:13 :: administrator -> marcelo.pazos@inpe.br :: 2013
2018-08-27 12:47:55 :: marcelo.pazos@inpe.br -> administrator :: 2013
2021-02-11 18:29:53 :: administrator -> marcelo.pazos@inpe.br :: 2013
3. Conteúdo e estrutura
É a matriz ou uma cópia?é a matriz
Estágio do Conteúdoconcluido
Transferível1
Tipo do ConteúdoExternal Contribution
Tipo de Versãopublisher
Palavras-ChaveActive thermal control systems
Design and application
Electronic component
Heat pipe technology
Loop pulsating heat pipes
Pulsating heat pipe
Surveillance systems
Thermal control devices
Heat pipes
Liquids
Temperature control
Security systems
ResumoSurveillance systems have proven to be important applications for high performance thermal control devices, especially the passive ones using heat pipe technology. With the growing need for heat dissipation presented by this type of system, usually hybrid solutions are designed, which include both liquid cooling and passive two-phase thermal control. This last one is usually applied when the heat source is located far from the heat sink and the use of liquid cooling or any other active thermal control system is not possible due to the lack of available space for integration. Since most of the surveillance systems being designed today require thermal control devices that operate under adverse orientation, some restrictions apply. Therefore, the technology that is currently used and disseminated for aerospace missions can find many other applications on surveillance systems for defense purposes. With severe restrictions regarding available space for integration of common thermal control devices, the design and application of pulsating heat pipes become the most indicated solution for the present investigation. Previous investigations have demonstrated that pulsating heat pipes configured as an open loop can operate on adverse conditions, promoting the heat transport from the source to the sink with good reliability. Based on this fact, this investigation is focused on presenting the thermal management of electronic components of a surveillance system being done by pulsating heat pipes configured as open loops. Despite the relatively high temperature difference between the heat source and sink, the open loop pulsating heat pipe is able to transport the rejected heat from the electronic components to a remote heat dissipation area, while keeping their temperatures within the required range established by the project. The operation of the pulsating heat pipes have proven to be stable and reliable, meeting the project's expectations for thermal control.
ÁreaETES
Arranjo 1urlib.net > BDMCI > Fonds > Produção pgr ATUAIS > CMC > Pulsating heat pipes...
Arranjo 2urlib.net > BDMCI > Fonds > Produção anterior à 2021 > DIDMC > Pulsating heat pipes...
Conteúdo da Pasta docacessar
Conteúdo da Pasta sourcenão têm arquivos
Conteúdo da Pasta agreementnão têm arquivos
4. Condições de acesso e uso
URL dos dadoshttp://mtc-m21b.sid.inpe.br/ibi/8JMKD3MGP5W34M/3FA462C
URL dos dados zipadoshttp://mtc-m21b.sid.inpe.br/zip/8JMKD3MGP5W34M/3FA462C
Idiomaen
Grupo de Usuáriosadministrator
marcelo.pazos@inpe.br
Grupo de Leitoresadministrator
marcelo.pazos@inpe.br
Visibilidadeshown
Permissão de Atualizaçãonão transferida
5. Fontes relacionadas
Repositório Espelhoiconet.com.br/banon/2006/11.26.21.31
Unidades Imediatamente Superiores8JMKD3MGPCW/3F2UALS
8JMKD3MGPCW/446AF4B
Lista de Itens Citando
Acervo Hospedeirosid.inpe.br/mtc-m21b/2013/09.26.14.25.20
6. Notas
Campos Vaziosarchivingpolicy archivist booktitle callnumber copyholder copyright creatorhistory descriptionlevel dissemination doi edition editor format issn lineage mark nextedition notes numberofvolumes orcid pages parameterlist parentrepositories previousedition previouslowerunit progress project publisher readpermission resumeid rightsholder schedulinginformation secondarydate secondarykey secondarymark serieseditor session shorttitle sponsor subject targetfile tertiarymark tertiarytype type url volume
7. Controle da descrição
e-Mail (login)marcelo.pazos@inpe.br
atualizar 


Fechar